ENTER THE WATER WHEN A UNIT IS IN OPERA-

TION!

TIMER-OPERATION INSTRUCTIONS

C-25 Control Box will turn the aerator/fountain ON &

OFF with the TIMER. Kasco lights will turn ON with the

PHOTO EYE and OFF with TIMER. C-25 Control Box is

to be used with Kasco Approved Lights ONLY!

• Insert “ON” (GREEN) and “OFF” (RED) trippers into

dial at desired ON and OFF times.

• Turn dial clockwise one or more revolutions until

correct time-of-day (AM or PM) in window is aligned

with the arrow.

• Plug aerator/fountain cord into the RIGHT hand outlet

(labeled UNIT).

• Plug transformer light cord into LEFT hand outlet

(labeled LIGHT).

FOR TEMPORARY MANUAL OPERATION

Rotate MANUAL knob counter-clockwise to desired ON or

OFF position. Timer will follow next automatic operation.

into the 120V power supply on the post and ENJOY YOUR

NEW KASCO AERATOR!

4. Test the GFCI with the test button now and every 30

days.

Any unauthorized modifications to this control panel will

void the UL listing and the Kasco warranty.

C-25 Timer Control Instructions

Portable Timer with Ground Fault Interrupter

(Unit: 15 FLA, 90 LRA 120 VAC

Light: 900 W, 120 VAC)

IMPORTANT

This portable timer is designed for CONTROLLING the

connected equipment only. Unplug timer before servic-

ing the unit or the equipment it controls. THE MANUAL

OVERRIDE KNOB IS NOT TO BE USED AS A POWER

DISCONNECT! For maximum protection against electri-

cal shock hazard, perform test procedure on G.F.C.I. at least

once a month. Mount at least 5 ft. from open water.

G.F.C.I. TEST PROCEDURE

The G.F.C.I. should be checked every month to make sure

that it is operating properly. Just follow the simple instruc-

tions below. It is recommended to maintain a maintenance

diary of your monthly safety check.

1. Push TEST button, RESET button should pop out from

inner surface. This should result in power being OFF at

the outlet protected by the G.F.C.I. Verify by plugging a

test lamp into the outlet. Be sure the timer is in the ON

position.

2. If the G.F.C.I. tests okay, restore power by pushing the

RESET button back in. THE RESET BUTTON MUST BE

PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT

LOCKS AND RE-MAINS DEPRESSED AFTER PRES-

SURE HAS BEEN REMOVED.

DANGER: IF RESET BUTTON DOES NOT POP OUT,

IF TEST LAMP REMAINS LIT WHEN RESET BUTTON

DOES POP OUT, OR IF THE G.F.C.I. FAILS TO RE-

SET PROPERLY, DO NOT USE TIMER! CONTACT A

QUALIFIED SERVICE TECHNICIAN!

Failure to use the C-25 with Kasco Fountains will void the

warranty and cause the Fountain to not be listed to UL and

CSA standards via ETL.

UNDER NO CIRCUMSTANCES SHOULD ANYONE