The following maintenance procedures can be
utilized to ensure many years of quality perfor-
mance from your Kasco Fountain and reduce
the need for more costly repair work.
PROPER INSTALLATION: Proper installa-
tion of Kasco equipment will include a power
source with ground fault interruption. For
Fountain models, the C-25 control (120V)
included with the unit has built-in ground fault
interruption that is suffi cient. Ground fault
interrupters are a safety feature that can also
alert you to electrical leaks in the equipment.
It is extremely important to test the GFI upon
installation, each reinstallation, and monthly
thereafter to ensure proper operation. If you
have repeat, consistent trips on your ground
fault, the equipment should be disconnected
and removed from the water. The power
cord should be inspected for damage and you
should call Kasco Marine at 715-262-4488 for
further instructions or email Kasco at ser-
[email protected].
OBSERVATION: Operating equipment
should be observed on a regular basis (daily,
if possible) for any reduction or variation in
performance. If a change in performance is
observed, the equipment should be disconnect-
ed from power and inspected for any material
that may have clogged the system or wrapped
around the shaft of the motor, especially plas-
tic bags and fi shing line. Even though Kasco
Aerators and Fountains are among the most
clog-resistant on the market, it is impossible
to protect against all items that can clog equip-
ment and still maintain a fl ow of water. These
materials can be very damaging to the equip-
ment under continued operation and must be
removed as soon as possible. ALWAYS UN-
PLUG THE UNIT BEFORE ATTEMPTING
TO REMOVE CLOGS.
CONTACT A QUALIFIED SERVICE TECH-
NICIAN!
Failure to use the C-25 with Kasco Fountains
will void the warranty and cause the Fountain
to not be listed to UL and CSA standards via
ETL.
UNDER NO CIRCUMSTANCES SHOULD
ANYONE ENTER THE WATER WHEN A
UNIT IS IN OPERATION!
TIMER-OPERATION INSTRUCTIONS
C-25 Control Box will turn the aerator/foun-
tain ON & OFF with the TIMER. Kasco lights
will turn ON with the PHOTO EYE and OFF
with TIMER. C-25 Control Box is to be used
with Kasco Approved Lights ONLY!
Insert “ON” (GREEN) and “OFF” (RED)
•
trippers into dial at desired ON and OFF
times.
Turn dial clockwise one or more revolu-
•
tions until correct time-of-day (AM or PM)
in window is aligned with the arrow.
Plug aerator/fountain cord into the RIGHT
•
hand outlet (labeled UNIT).
Plug transformer light cord into LEFT hand
•
outlet (labeled LIGHT).
FOR TEMPORARY MANUAL OPERATION
Rotate MANUAL knob counter-clockwise to
desired ON or OFF position. Timer will fol-
low next automatic operation.
Maintenance Recommendations
** Under No Circumstances should anyone
enter the water while a fountain is operating.
** Please keep the original box for mainte-
nance shipping.