Kasco Marine 1400JFL User Manual
Page 8

8
C-25 Timer Control
Portable Timer with Ground Fault Interrupter
(Unit: 9.8 FLA, 58.8 LRA 120 VAC
Light: 300 W, 120 VAC)
IMPORTANT
This portable timer is designed for CON-
TROLLING the connected equipment only.
Unplug timer before servicing the unit or
the equipment it controls. THE MANUAL
OVERRIDE KNOB IS NOT TO BE USED
AS A POWER DISCONNECT! For maxi-
mum protection against electrical shock haz-
ard, perform test procedure on G.F.C.I. at least
once a month. Mount at least 5 ft. from open
water.
G.F.C.I. TEST PROCEDURE
The G.F.C.I. should be checked every month
to make sure that it is operating properly. Just
follow the simple instructions below. It is rec-
ommended to maintain a maintenance diary of
your monthly safety check.
Push TEST button, RESET button should
•
pop out from inner surface. This should
result in power being OFF at the outlet pro-
tected by the G.F.C.I. Verify by plugging a
test lamp into the outlet. Be sure the timer
is in the ON position.
If the G.F.C.I. tests okay, restore power by
•
pushing the RESET button back in. THE
RESET BUTTON MUST BE PUSHED
FIRMLY AND FULLY INTO PLACE
UNTIL IT LOCKS AND REMAINS DE-
PRESSED AFTER PRESSURE HAS
BEEN REMOVED.
DANGER: IF RESET BUTTON
DOES NOT POP OUT, IF TEST LAMP RE-
MAINS LIT WHEN RESET BUTTON DOES
POP OUT, OR IF THE G.F.C.I. FAILS TO
RESET PROPERLY, DO NOT USE TIMER!
Eagle’s Nest:
Produces a wide “V” pattern of water 3.5 feet
high by 10 feet in diameter.
This nozzle does not use the upper pump
housing. It has the number 4 molded near the
screw collar of the nozzle.
Hawk’s Nest:
Produces a narrow “V” pattern of water 3 feet
high by 7 feet in diameter.
This nozzle does not use the upper pump
housing. It has the number 5 molded near the
screw collar of the nozzle.
Upper Pump Housing:
Must be installed
and used with the
Osprey, Condor, and
Falcon nozzles. Must
be removed to use
the Eagle’s Nest and
Hawk’s Nest nozzles.
Hint: Keep the osprey
nozzle attached to the
upper pump housing to help you pull the up-
per pump housing out of the fountain tube
for cleaning or nozzle changes.