C-25 Timer Control

Portable Timer with Ground Fault Interrupter
(Unit: 9.8 FLA, 58.8 LRA 120 VAC
Light: 300 W, 120 VAC)

IMPORTANT
This portable timer is designed for CON-
TROLLING the connected equipment only.
Unplug timer before servicing the unit or
the equipment it controls. THE MANUAL
OVERRIDE KNOB IS NOT TO BE USED
AS A POWER DISCONNECT! For maxi-
mum protection against electrical shock haz-
ard, perform test procedure on G.F.C.I. at least
once a month. Mount at least 5 ft. from open
water.

G.F.C.I. TEST PROCEDURE
The G.F.C.I. should be checked every month
to make sure that it is operating properly. Just
follow the simple instructions below. It is rec-
ommended to maintain a maintenance diary of
your monthly safety check.

Push TEST button, RESET button should

pop out from inner surface. This should
result in power being OFF at the outlet pro-
tected by the G.F.C.I. Verify by plugging a
test lamp into the outlet. Be sure the timer
is in the ON position.
If the G.F.C.I. tests okay, restore power by

pushing the RESET button back in. THE
RESET BUTTON MUST BE PUSHED
FIRMLY AND FULLY INTO PLACE
UNTIL IT LOCKS AND REMAINS DE-
PRESSED AFTER PRESSURE HAS
BEEN REMOVED.

DANGER: IF RESET BUTTON

DOES NOT POP OUT, IF TEST LAMP RE-
MAINS LIT WHEN RESET BUTTON DOES
POP OUT, OR IF THE G.F.C.I. FAILS TO
RESET PROPERLY, DO NOT USE TIMER!

Eagle’s Nest:

Produces a wide “V” pattern of water 3.5 feet
high by 10 feet in diameter.

This nozzle does not use the upper pump
housing. It has the number 4 molded near the
screw collar of the nozzle.

Hawk’s Nest:

Produces a narrow “V” pattern of water 3 feet
high by 7 feet in diameter.

This nozzle does not use the upper pump
housing. It has the number 5 molded near the
screw collar of the nozzle.

Upper Pump Housing:

Must be installed
and used with the
Osprey, Condor, and
Falcon nozzles. Must
be removed to use
the Eagle’s Nest and
Hawk’s Nest nozzles.
Hint: Keep the osprey
nozzle attached to the

upper pump housing to help you pull the up-
per pump housing out of the fountain tube
for cleaning or nozzle changes
.