beautypg.com

Key features – General Tools and Instruments BF10 User Manual

Page 4

background image

The plug-in transmitter also doubles as a socket tester. By
measuring leakage currents, it can identify five common
outlet wiring faults: missing earth (ground), missing neutral,
live and earth reversed, live and neutral reversed, and open
circuit. The type of fault is indicated by a unique pattern of
colored LEDs on the front of the transmitter as well as the
pulsed tone that it emits.

The BF10 is NOT a comprehensive diagnostic instrument:

• It cannot test the ground fault circuit interruption function of

GFCI receptacles.

• It cannot measure the quality of earth (ground) connections,

detect two hot wires or more than one fault in a circuit, or
detect reversed grounded and grounding conductors.

The BF10 is a simple instrument for detecting common
improper wiring of GFCI and non-GFCI outlets. All detected
problems should be referred to a qualified electrician.

If you need a comprehensive diagnostic instrument, General
recommends its CA10 Circuit Analyzer. For details, visit
www.generaltools.com and enter “CA10” in the SEARCH box.

KEY FEATURES

• Automatically locates the breaker or fuse associated with any

110V outlet without tripping the breaker or blowing the fuse

• Also identifies five common outlet wiring faults

4