beautypg.com

Fairbanks IM 6000 Series In-Motion Scale System with FB3000 User Manual

Page 22

background image

50792

22

05/05 Issue #1

A.

Errors

Symptom

Solution

Load Cell Failure(s)

Weight is behind zero by a large
amount. Check for binds in the
platform.

Load cell has failed. Replace
cell.

No indication from

Check for +12vdc.

Green or Red Lamps
for Scanners

Check sensor wiring connections
or check for damage.

No Scale Port Found...

Check output from High Speed
A/D.

Check interface cable for broken
wires.

Check COM 2 for proper opera-
tion.

Check for loose interface con-
nections

More than two boxes on the scale

Check sensor wiring connections
or check for damage.

Two boxes on the scale

Check physical box spacing and
spacing programming.

Error calculating box weight

Check scale calibration.

Section 5: Service and Maintenance