Fairbanks IM 6000 Series In-Motion Scale System with FB3000 User Manual
Page 12

50792
12
05/05 Issue #1
Range
The number of weights to include in the calculation before trimming.
Performance
Default = 1.0000. If this value is not 1.0000, the final box weight calculation =
Factor
box weight + (box weight * Performance Factor). If the Performance Factor
is greater than 1.0000, the final box weights are increased, if less than 1.0000,
the final box weights are decreased.
Box Tolerance If this value is other than the default value of 0.00, any weights read for the box
on the scale that are outside the initial average box weight calculation for this
box are discarded when the final box weight is derived.
Use Peak
After Trim Min/Peak trimming has occurred, the Peak Weight of the remaining
Weight Only
box weights are used as the final box weight calculation.
Trim Peak
The greatest box weight(s) gathered from On to Off Scanner is discarded.
Trim Min
The lightest box weight(s) gathered from On to Off Scanner is discarded.
On Scanner 1
Port setting on the Digital I/O card for the on sensor. Default setting: A0
On Scanner 2 Not Used. Port setting for a second on sensor. Default setting: [BLANK].
Off Scanner
Port setting on the Digital I/O card for the off sensor. Default setting: A2
Invert Sensors This setting is for the various types of photoelectric sensors. Some sensors are
NPN and others are PNP. NPN sensors = unchecked box. PNP = checked
box.
AutoTare
This feature will store the tare of the item on the scale when selected. this fea-
ture is disabled for use with the in motion process. This setting will effect scale
perfomance. For authorized personnel only.
Configuration This menu accesses general configuration functions of the indicator.
Menu
This setting will effect scale perfomance. For authorized personnel only.
Service Menu
This menu accesses calibration and other metrological functions of the indicator.
This setting will effect scale perfomance. For authorized personnel only.