beautypg.com

Fairbanks 5001 Series QuickSilver IS User Manual

Page 16

background image

50770

16

04/12 Rev. 5

5. With the appropriate TARGET weight displayed, press the same

OVER/UNDER key, 1, 2, 3, or 4 as was pressed in Step 2.

6. To change the LIMIT WEIGHT, press the DOWN key. The display will

show the current limit weight in memory as a four digit number.

7. Press the UP key to increase the limit weight or the DOWN key to

decrease the limit weight.

8. With the appropriate LIMIT weight displayed, press the same

OVER/UNDER key, 1, 2, 3, or 4 as was pressed in Step 2.

9. Repeat this process for each of the four OVER/UNDER programs.

g. Over/Under Weighing

1. Press the OVER/UNDER key, 1, 2, 3, or 4, that is to be used in the

weighing operation. The display will show the appropriate
OVER/UNDER graphic.

2. Place the item to be weighed on the platform. The indicator in the

display will move to show the weight as being UNDER, OVER, or on
TARGET.

3. Add or remove material from the platform until the indicator shows on

target.

4. Remove the material from the platform and repeat the process.

h. Exit Over/Under Weighing

To exit the Over/Under Weighing Mode, press the GROSS/NET key. The
indicator will return to the Weigh Mode.

Note: When the arrow keys are pressed, Fine adjustment changes the last two digits,
Coarse adjustment changes the first two digits. The operator can toggle between fine and
coarse adjustments by pressing the [UNITS] key.