Fairbanks 5001 Series QuickSilver IS User Manual
Page 10
Section 4: Security
50770
10
04/12 Rev. 5
A. Security Levels
The QuickSilver IS is shipped with the least protected security level, 00, programmed into the
indicator. This level allows all parameters to be programmed from the front panel.
To change the security level to a more restricted condition, change program step "SL"
(security level) "10 00" to "10 01" or "10 02". Once a higher level is programmed, it
CANNOT be reduced to a lower level from the front panel. To reduce the security level, call a
qualified service representative.
The security levels are:
00 - No programmable parameters are protected and all of them can be changed from
the front panel. This security level can only be used in NON-COMMERCIAL
applications.
01 - Limited parameters are protected and P3 through P9 can be changed from the
front panel. This security level can be used in commercial applications.
02 - All programmable parameters are protected and NO changes can be made from
the front panel. This security level may be used in commercial applications.
03 - Same as 00.
If the scale is to be used in a commercial application, it must be placed-in-service by a
certified technician or an official from the weights and measures department. To be
used as a commercial scale, the security level must be set to 01 or 02.