Trouble shooting – Bosch TDS4530 User Manual
Page 21
21
BOSCH
ENGLISH
Trouble shooting
Problem
Possible causes
Solution
Pilot light (11)
flashes
• Boiler and filter must be rinsed.
• Rinse the filter and the boiler according
to the cleaning instructions in this
manual (see section E).
The steam generator
does not come on.
• There is a connection problem.
• The main power button is not
switched on.
• Check the mains cable (6), the plug
and the socket.
• Set the main power button (12) to the
“I” position (illuminated in red).
The iron does not
heat up.
• The main power button is not
switched on.
• The temperature is set to a low
position.
• Set the main power button (12) to the
“I” position (illuminated in red).
• Set the temperature to the desired
position.
The iron begins to
smoke when
switched on.
• During first use: certain
components on the appliance
have been lightly greased at the
factory and may produce a little
smoke when initially heated.
• During subsequent use: the
soleplate may be soiled.
• This is completely normal and will stop
after a short while.
• Clean the soleplate according to the
cleaning instructions in this manual.
Water flows through
the holes on the
soleplate.
• The steam function is being used
before it has reached the correct
temperature.
• The water is condensing inside
the pipes because steam is being
used for the first time or has not
been used for a long time.
• The steam generator contains too
much scale.
• Reduce the steam flow when ironing at
low temperatures.
• Point the iron away from the ironing
area and press the steam release
button until steam is produced.
• Clean the boiler as described in
section “Calc'n'Clean Advanced” (E).
Dirt comes out
through the
soleplate.
• There is a build up of scale or
minerals in the steam tank.
• Chemical products or additives
have been used.
• Use tap water mixed 50% with distilled
or demineralised water. To prolong the
optimum steam function, mix tap water
with distilled water 1:1. If the tap water
in your district is very hard, mix tap
water with distilled water 1:2.
• Clean the soleplate with a damp cloth.
• Never add products to the water.
The iron does not
produce any steam.
• The boiler is not switched on or
the water tank is empty.
• The steam regulation is set to the
minimum position.
• Set the main power button (12) to the
“I” position (illuminated in red), and/or
fill the water tank.
• Increase the steam flow (see section
B).
The ironed garment
turns dark and/or
sticks to the
soleplate.
• The selected temperature is too
high and has damaged the
garment.
• Select a suitable temperature for the
material being ironed and clean the
soleplate with a damp cloth.
The soleplate turns
brown.
• This is a regular consequence of
continued use over a long period
of time.
• Clean the soleplate with a damp cloth.
Problem
Possible causes
Solution
The appliance
makes a pumping
sound.
• Water is being pumped into the
steam tank.
• Water tank (1) is not correctly
inserted in the housing.
• The sound will not stop.
• This is normal.
• Adjust the water tank to fit correctly.
• If the sound will not stop, do not use
the steam generator and contact an
authorised technical service centre.
Loss of pressure
during ironing.
• Steam release button has been
activated for too long a period of
time, that is, it has been pressed
too frequently.
• Use the steam release button at
intervals. This improves the ironing
result as the textiles will be steamed,
dried and ironed properly.
Water spots appear
on the garment
during ironing.
• May be caused by steam
condensed on the ironing board.
• Wipe the textile cover of the ironing
board, and iron any water drops to dry
them.
Water spots appear
on the garment
during use of the
“PulseSteam”
function.
• Water spots are caused by steam
condensation in the hose when
cooling down after use.
• Water drops stop coming out of the
soleplate after using the “PulseSteam”
function for some time.
The hose gets hot
during use.
• This is normal. It is caused by the
steam passing through the hose
during steam ironing.
• Place the hose on the opposite side so
that you cannot touch the hose during
ironing.
Water leakage from
the boiler.
• Filter (4) located at the side of the
appliance is loose.
• Tighten up the filter.
The iron does not
stop steaming after
placing it on the pad
(2).
• “PulseSteam” function has been
activated by double click.
• Just press the trigger once again and
the iron will stop steaming at once.
If the above does not solve the problem, get in touch with an authorised technical service.
You can download this manual from the local homepages of Bosch.