Building Technologies Division

ID-MP Inner Door Mounting Plate
The Inner Door Mounting Plate (Model ID-MP) is

mounted on the inner door of any given model CAB

enclosure. Model ID-MP plates are used to mount

switch-control modules (Model SCM-8); LED control

modules (Model LCM-8), or fan-control modules (Model

FCM-6).
Four (4) mounting plates are included in each Model ID-

MP. Each mounting plate has four (4) spaces for control

modules, and can hold either four (4) Model SCM-8

modules (one [1] control module space for each

module); four (4) LCM-8 (one [1]control module space

for each module), or two (2) Model FCM-6 modules (two

[2] module spaces for each module).
Combinations are also allowed. Blank spaces in Model ID-

MP can be covered using the blank-control-module

plate (Model BCM). Up to four (4) Model ID-MP

modules can be mounted in a single row on the inner

door.

ID-SP Inner Door Blank Single Plate

ID-SP Inner Door, Blank Single Plate
The Inner Door, Blank Single Plate (Model ID-SP) is used to

cover any single-module blank spaces on the inner door

not used to mount Model PMI or Model ID-MP. Up to

four (4) Model ID-SP modules can be mounted in a
single row on the inner door. Two (2) blank plates are

included in each Model ID-SP.

ID-FP Inner Door Full-Blank Plate
Model ID-FP is a blank plate that covers the full opening of

the row on an inner door, and is used for applications

requiring full, dead-front protection. A single, full blank

plate is included in Model ID-FP.

BCM Blank Control Module Plate

BCM Blank Control-Module Plate
Model BCM plates can be mounted on a single ID-MP.

Four (4) blank module plates are included in each

Model BCM.

OD-LP Outer Door Lens Plate

OD-LP Outer Door Lens Plate
The Model OD-LP is a clear plastic lens plate mounted

on the outer door of a system cabinet. It is used to allow

operators to see the system interface and controls

mounted on the inner door, but restricts access to

unauthorized users. It covers an entire row on the outer

door. A single lens plate is included with each OD-LP.

OD-BP Outer Door Blank Plate

OD-BP Outer Door Blank Plate
The Model OD-BP is used to cover an entire row on the

outer door of a system cabinet. It is used when there is

no PMI or control modules mounted on the adjacent row of

the inner door. A single, blank plate is included in each OD-

BP.

OD-GP Outer Door Grill Plate

OD-GP Outer Door Grill Plate
The Model OD-GP also covers an entire row on the outer

door of a system cabinet, but has four rows of ventilation

louvers on it. The OD-GP is mounted in front of system

bulk amplifiers, card amplifiers, or other modules that

generate heat. Using the OD-GP will permit airflow across

these modules to aid in heat dissipation. A single grill

plate is included with each OG-GP.