FIREPOWER Firefinder XLS User Manual
Page 7
s
Industry, Inc.
Building Technologies Division
System-Status Display
SSD Series System-Status Display
The System Status Display (SSD Series Models) is a remote
LED / LCD display that shows the local status of a FireFinder
XLS system. An LED illuminates when Alarm, Supervisory,
Trouble, and Security events occur on the system. A (4)
four-line liquid-crystal display (LCD) will give details of
the event in alphanumeric form.
The display can be toggled to display additional events.
Optional remote system control capabilities are available.
Models SSD-C, SSD-C-INT, and Model SSD-C-REM have three
(3) additional control buttons to acknowledge events,
silence audible circuits, and reset the system. Models
SSD-C and SSD-C-INT have an integral keyswitch that
enables these control buttons to operate.
Model SSD-C-REM is located within a locked cabinet.
Hence, no additional keyswitch is required for enabling
the control buttons.
CAB1 Single Row Enclosure
CAB1 Single Row Enclosure
Model CAB 1, the smallest of the FireFinder XLS enclosures,
can house a single Model CAB-MP cabinet mounting plate
for mounting card cages, power supplies and bulk
amplifiers. Model CAB1 also has four (4) mounting slots
on the inner door for mounting Model PMI and Model ID-MP
switch module brackets.
Model CAB1 comes complete with a black back box; black
inner and outer doors; a single lock and key set on the outer
door; a single CAB-MP cabinet mounting plate (installed),
and a single OD-LP outer door lens plate (installed). A red
version (Model CAB1-R) is also available – approximate
size: 27" (68.6cm.) high, 26" (66cm.) wide, and 8"
(20.3cm.) deep.
MDACT - Multi-Point Digital Alarm
Communicator Transmitter
MDACT - Multi-Point Digital Alarm Communicator
Transmitter
The Multi-Point Digital Alarm Communicator Transmitter
(Model MDACT) is used in FireFinder XLS systems where
point identification of alarm, supervisory, security and
trouble events is required at Central or Remote Receiving
Stations. An intelligent RS-485 communications protocol
transmits all system information to Model MDACT.
The installer selects the specific event or groups of
events that are set to transmit from Model MDACT over
phone lines to listed receiving station equipment. In turn,
Model MDACT can transmit point information, via the
Ademco Contact ID and the SIA protocol. A Mounting Plate
(Model MOM2-XMP), MOM-2 card cage, and an XMI
Interface Card are required for installation.
TSP-40A Thermal Strip Printer
TSP-40A Thermal Strip Printer
The thermal strip printer (Model TSP-40A) is designed for
use with the FireFinder XLS system. Model TSP-40A acts
as an event-logging device, providing a permanent history
report of all system activity. Model TSP-40A mounts in
the FireFinder XLS Model CAB 1, Model CAB2 or Model
CAB3 enclosure, and its printout is visible through a
window in the locked-door enclosure. Printouts are
automatically spooled onto a take-up reel for tidy, uniformed
records storage.