7.2.4 Parameter display mode
Parameter means a group of values that configures a fastening operation. Combined these
values are named preset data. The AFC1100 system can store up to 8 different parameters
that can be selected by WORK SELECT 0 ~ 2 (see section 4.7.2) PLC inputs.
In addition to parameter 1 ~ 8 there is a PARAMETER 0 that contains configuration data
common to all parameters.
PARAMETER 1
2
3
4
5
6
7
8
(PRESET VALUES)
CAL TORQUE
LOW TORQUE
HIGH TORQUE
STD TORQUE
SPEED CHANGE TORQUE
1ST TORQUE
SNUG TORQUE
THR TORQUE
CROSSOVER TORQUE
LOW ANGLE
HIGH ANGLE
FINAL ANGLE
1ST ANGLE
CROSSOVER ANGLE
1ST TORQUE RATE LOW
1ST TORQUE RATE HIGH
2ND TORQUE RATE HIGH
2ND TORQUE RATE LOW
INITIAL TIME
1ST TIME
FINAL TIME
FREE RUN SPEED
SLOW DOWN SPEED
TORQUE SPEED
REVERSE SPEED
FREE RUN TURN
PARAMETER 0
SYSTEM PARAMETERS
TORQUE UNIT: Kg-m, Kg-cm, Nm, Ft-Lb, In-Lb
PARAMETER 1-8, when using the same tool setting..
TOOL SETTINGS used with PARAMETER 1
TOOL SETTINGS used with PARAMETER 2
TOOL SETTINGS used with PARAMETER 3
TOOL SETTINGS used with PARAMETER 4
TOOL SETTINGS used with PARAMETER 5
TOOL SETTINGS used with PARAMETER 6
TOOL SETTINGS used with PARAMETER 7
TOOL SETTINGS used with PARAMETER 8