FEC AFC1100 User Manual
Page 8

)(& ,QF
7.2.3 Fastening results display mode.
In fastening results display mode (when [D-NO] shows _0 ~
≡≡≡≡
4), data can be obtained by
pressing the [
↓↓↓↓
] and [
↑↑↑↑
] keys to scroll [D-NO] until the desired DATA item is displayed. The
following information will be displayed in the [DATA] and [ANGL/SPNO] display sections for
the displayed [D-NO]:
ANGLE @ PEAK TORQUE.
FINAL TORQUE.
≡≡≡≡
4
1ST PEAK ANGLE.
1ST PEAK TORQUE.
≡≡≡≡
3
1ST FINAL ANGLE.
1ST FINAL TORQUE
≡≡≡≡
2
2ND INCREMENT ANGLE.
2ND INCREMENT TORQUE.
≡≡≡≡
1
1ST INCREMENT ANGLE.
1ST INCREMENT TORQUE.
≡≡≡≡
0
5: ACCEPT.
4: REJECT.
3: STOP SIGNAL.
2: BYPASS SIGNAL.
1: ABNORMAL SIGNAL.
0: RESET / NO DATA / AFTER REVERSE.
SPINDLE NO
CAUSE OF FASTENING STOP:
=5
SPINDLE NO
REVERSE FLAG (ON: BACKED OUT, OFF: NOT BACKED
OUT)
=4
SPINDLE NO
SELF CHECK (ON: enabled, OFF: disabled)
=3
SPINDLE NO
NOT USED
=2
SPINDLE NO
FASTENING STEPS
=1
SPINDLE NO
FASTENING MODE.
====
0
SPINDLE NO
FASTENING MODE.
_7
SPINDLE NO
CYCLE TIME
_6
SPINDLE NO
FINAL STEP TIME.
_5
SPINDLE NO.
1ST STEP TIME.
_4
SPINDLE NO
2ND TORQUE RATE.
_3
SPINDLE NO.
1ST TORQUE RATE
_2
SPINDLE NO.
FINAL ANGLE
_1
FINAL ANGLE.
PEAK TORQUE.
_0
ANGL/SPNO
DATA
D-No
D-NO
DATA
PEAK TORQUE
FINAL ANGLE
OR
ANG/SPNO
_
_0
_1
_2
_3
1ST TORQUE RATE
2ND TORQUE RATE
(DISPLAY [D-No]
DATA DISPLAYED
FIG. 7-2-3 Fastening results display selection
Chapter 7: System Operations (Rev. 8/98)
Page 7-8