6

1/2

1/2

1/3

Label 16

A

B

C

C

40

The out of balance switch is mounted on the solid part of the machine.

There is a window around the probe of the out of balance switch that is mounted

on the movable part of the machine.
When the machine goes out of balance by overloading or uneven distribution of

the linen, the out of balance switch will interrupt this action to prevent damage to

the machine.

Important

Out of balance switch

To guarantee good functioning, the probe should be centered horizontally

and vertically at 1/3 from the bottom of the out of balance window (when

machine drum is empty). (See Label 16)

Window

Probe

To open the door in case of an emergency (deficiencies, etc.), remove the lock

cover plate (A). Subsequently, insert a screwdriver from the left-hand side behind

the lock mechanism (B) and push back the black handle (C) while opening the

doorhandle.

Opening the door in

case of an emergency

Important

Before opening the door, be sure there is no water left in the tub and

that the drum has come to a complete stop.

This manual is related to the following products: