Warning – Alliance Laundry Systems HF900 User Manual
Page 33

4
33
WARNING
The washer-extractor should be connected to an individual branch
circuit not shared with lighting or other equipment.
Electrical Specifications HF900, IHF900
900 liters / 200 pounds
Boiler Fed/Steam Heat
Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Recommended Circuit
Breaker (US-market)
AWG/mm2
kW Standard
Heating Elements
Full Load
Amps
Recommended
Circuit Breaker
AWG/mm2
US NON-US
US NON-US
N
440-480 50/60
3
3+PE
44
50
50
8/10.0
9x4 kW
96
N/A
100
2/40
P
380-415 50/60
3
3+N+PE 44
50
50
8/10.0
96
N/A
100
2/40
Q
200-240 50/60
3
3+PE
85
90
90
4/25.0
9x3 kW
153 N/A
180
4/0 /
100
X
200-240 50/60
1/3
2/3+PE N/A N/A
N/A
N/A
N/A N/A
N/A
N/A
Alternative Electric Heat Options
N
440-480 50/60
3
3+PE
9x3 kW
83
N/A
90
2/40
P
380-415 50/60
3
3+N+PE
83
N/A
90
2/40
Q
200-240 50/60
3
3+PE
153 N/A
180
4/0 /
100
X
200-240 50/60
1/3
2/3+PE
N/A N/A
N/A
N/A
Table 5