Interferometer

Appendix

Maintenance

IMPORTANT: All mirrors on the inter-

ferometer should be cleaned ONLY with alcohol
and a soft cloth. Other cleaning solvents, such as
Windex, may scratch or dissolve the aluminized
front surface of these mirrors.

Besides cleaning the mirrors, no other maintenance is
required. If the mylar strip gets damaged, or a severe
shock causes the interferometer to lose its alignment,
return the unit to PASCO scientific for repair.

Replacement Parts

The following spare parts are available from PASCO
scientific:

Item

PASCO Part No.

Vacuum cell assembly

003-02197

Convex lens, 18 mm Focal Length

003-02281

Three point adjustable mirror assembly 003-02671

Beam-Splitter assembly

003-02672

Movable mirror assembly

003-02673

Component Holder

648-02696