Ideal Gas Law Apparatus

Model No. TD-8596A

8

®

Varying Temperature, Sample Data and Analysis

Percent Difference = 1%

Answers to Questions

1. When the cylinder is compressed, the pressure momentarily spikes because the temperature

of the gas increases. As the temperature drops back down, the pressure decreases.

2. The pressure does not return to its original value because volume has decreased while the

molar quantity of gas remains the same.

3. When the pressure is released the temperature drops rapidly, then slowly returns to room

temperature. The temperature drops due to sudden decompression (which is essentially
adiabatic). It returns to room temperature due to heat flow from the environment into the
syringe.

Table 2: Varying Temperature

Volume (cc)

Pressure (kPa)

Temperature (K)

1

43.6

99.76

301.04

2

23.6

199.22

321.08

P

1

V

1

T

1

------------

14.4 kPa cc K

=

P

2

V

2

T

2

------------

14.6 kPa cc K

=