Pach and Company AeGIS 4000P Manual User Manual
Page 26

94
AUXILIARY
MODE
AUXILIARY
INPUT CAN BE
USED FOR
TIMER, DOOR
RELEASE
SWITCH, ETC.
95
ALARM MODE
THE SYSTEM
WILL BEEP OR
CALL THE
REMOTE PHONE
IF INVALID
ACCESS CODES
ARE ENTERED.
Step 1
Entering The Programming
Mode: Press 0 and # simultaneously
then release. If you are in the pro-
gramming mode, proceed to step 2.
Step 2
Enter the 4-digit Master
Code (factory default is 0000) and you
will hear “One Short Beep”. If you
entered an invalid master code you will
hear “One Long Beep”, repeat
step 1. Should your master code
become lost or forgotten Reset Master
Code.
Step 3
Enter 94 then #, you will
hear “One Short Beep”.
Step 4
Enter
0 = AUXIN is disabled or
1 = is enabled and door will open
according to Door Open Interval
programmed on function Code
“92”) or
2 = AUXIN is enabled and opening
door is controlled by the AUXIN)
then press #, you will hear “One Short
Beep”.
Step 5
Enter another Function Code
to program another parameter other-
wise press
∗ to exit and you will hear
“Three Short Beeps”.
Step 1
Entering The Programming
Mode: Press 0 and # simultaneously
then release. If you are in the pro-
gramming mode, proceed to step 2.
Step 2
Enter the 4-digit Master
Code (factory default is 0000) and you
will hear “One Short Beep”. If you
entered an invalid master code you will
hear “One Long Beep”, repeat
step 1. Should your master code
become lost or forgotten see Reset
Master Code.
Step 3
Enter 95 then #, you will
hear “One Short Beep”.
Step 4
Enter
0 for local (system’s speaker will beep
and the system will be blocked-out
for 60 seconds)
1 system will make an emergency call
to a premise or remote location and
the system will be blocked-out for 60
seconds then press #, you will hear
Step 1
Pick up the phone and wait
for a dial tone.
Step 2
Press # # and you will hear
“One Short Beep”.
Step 3
Press # and you will hear
“One Short Beep”.
Step 4
Enter the Function Code 94
then press #, you will hear “One Short
Beep”.
Step 5
Enter
0 = AUI is disabled or
1 = AUI is enabled, door open time is
control by door open interval
programmed on function code 92,
or
2 = AUI is enabled, door open time is
controlled by the AUI)
then press #, you will hear “One Short
Beep”.
Step 6
Enter another function code
to program a different parameter or
exit the program by pressing
∗ ∗ and
you will hear “Three Short Beeps”.
Step 1
Pick up the phone and wait
for a dial tone.
Step 2
Press # # and you will hear
“One Short Beep”.
Step 3
Press # and you will hear
“One Short Beep”.
Step 4
Enter the Function Code 95
then press #, you will hear “One Short
Beep”.
Step 5
Enter
0 = the system will beep via its
speaker or
1 = the system will call into a premise
or remote location) then press #,
you will hear “One Short Beep”.
Step 6
Enter another function code
to program a different parameter or
exit the program by pressing
∗ ∗ and
you will hear “Three Short Beeps”.
Step 5
Enter another function code
to program a different parameter or
exit the program by pressing
∗ ∗ and
you will hear “Three Short Beeps”.
Step 1
Call to the AeGIS 4000P
system (you must know the system’s
phone number), you will hear: “One
Short Beep”, the gate is locked. “Two
Short Beeps”, the gate is unlocked.
Step 2
Press # then enter a valid
master code and you will hear:
• “One Short Beep”, the master code
is accepted then press # and you will
hear “One Short Beep”.
• “One Long Beep”, the master code
is rejected and the connection will be
disconnected.
Step 3
Enter the Function Code 94
then press #, you will hear “One Short
Beep”.
Step 4
Enter
0 = AUI is disabled or
1 = AUI is enabled, door open time is
control by door open interval
programmed on function code 92,
or
2 = AUI is enabled, door open time is
controlled by the AUI)
then press #, you will hear “One Short
Beep”.
Step 5
Enter another function code
to program a different parameter or
exit the program by pressing
∗ ∗ and
you will hear “Three
Short Beeps”.
Step 1
Call to the AeGIS 4000P
system (you must know the system’s
phone number), you will hear: “One
Short Beep”, the gate is locked. “Two
Short Beeps”, the gate is unlocked.
Step 2
Press # then enter a valid
master code and you will hear:
• “One Short Beep”, the master code
is accepted then press # and you will
hear “One Short Beep”.
• “One Long Beep”, the master code
is rejected and the connection will be
disconnected.
Step 3
Enter the Function Code 95
then press #, you will hear “One Short
Beep”.
Step 4
Enter
0 = the system will beep via its
speaker or
1 = the system will call into a premise
or remote location then press #,
you will hear “One Short Beep”.
Function
Local Programming
Premise Phone
Remote Phone
Pach and Company
Page 18
AeGIS 4000P
Chapter 3. Programming