Pach and Company AeGIS 4000RTP Quick Guide User Manual
Warning

PACH AND CO 1‐888‐678‐7224 Quick Reference
Download Complete Installation and Programming Manual at
www.pach‐co.com
 Missing Parts, contact Pach and Company 1-888-678-7224
 Defective system under manufacturer warranty,
CALL 1-888-678-7224 for advance replacement
24 Months warranty
for complete system, does not include
installation labor
6 Months warranty
for Printed Circuit Board, does not include
installation labor
PROGRAMMING FUNCTION CODES TABLE
Exit program, hold for 1 second 
to hang-up call 
76
Delete phone number on 70, 
71 and 72 
Save program or initiate 
program 
87
Disable or enable automatic 
call forwarding. 0= disable 
(default), 1= enable 
00
Change master code (0000 is 
default) 
88
Select automatic call 
forwarding 71 or 72 
01-20
Add individual access code for 
relay 1 
89
Select automatic call 
forwarding time 15-90 
seconds. Default= 15 
seconds. 
21-40
Add individual access code for 
relay 2 
90
Manually close or open relay 
1. 1= open, 0= close 
41-50
Add individual access code for 
relay 1 & relay 2 
91
Manually close or open relay 
2. 1= open, 0= close 
51
Relay 1 open time interval (01-
90 seconds) default 12 
seconds 
92
Talk time 10-90 seconds. 
Default= 60 seconds 
52
Relay 2 open time interval (01-
90 seconds) default 12 
seconds 
93
Lock-out count 03-09. 
Default= 03 
60
Delete all access codes 01-20
94
Auxiliary input (enable radio 
receiver) 
0= disable 
1= enable control by door 
open interval function code 
51. 
2= enable control by auxiliary 
input. 
61
Delete all access codes 21-40
95
Alarm Mode 
1= enable 
0= disable 
Default= 10 seconds local 
alarm. 
Default= 30 seconds remote 
62
Delete all access codes 41-50
96
System answer mode 
0= disable, default 
1-9= enable 1- 9 rings, when 
enable no call waiting feature. 
65
Delete all access codes
97
Do not disturb mode 
0= disable, default 
1= enable 
70
Direct call forwarding, phone 
number up to 11-digit. 
98
Select initiating premise call 
key 
0= * 
1= #, default 
71-72
Automatic or manual call 
forwarding, phone number up 
to 11-digit 
99
Set memory to factory default, 
then press 1# to confirm. 
WARNING:
DO NOT USE ON BOARD 12VDC and GND
TO POWER A DOOR STRIKE OR MAGNETIC LOCK 
SEPARATE POWER MUST BE USED TO POWER A DOOR 
STRIKE OR MAGNETIC LOCK. 