Pach and Company Quantum QC Series Quick Guide User Manual
Warning
Missing Parts, contact Pach and Company 1-888-678-7224
Defective system under manufacturer warranty,
call 1-888-678-7224 for advance replacement
24 Months warranty
for complete system
6 Months warranty
for Printed Circuit Board
Manuals are available online at www.pach-co.com
Exit program, cancel call
23
Lock-out Count
Save program
24
Alarm
0= disable
1= local beep for 60
seconds
2= disable system for 60
seconds with no beep
3= call directory (0-9)
00
Change master code (0000 is
default)
25
Keypad beep
0= disable (default)
1=enable
01
Add new forwarding tenant’s
directory
26
Door beep
0= disable
1= enable (default)
02
Edit existing tenant’s directory
27
Talk time (060-240
second). Default=60
second
03
Delete existing tenant’s
directory
28
Unlock relay1 time
(12-99 second). Default=
12 second
04
Clear all forwarding tenant’s
directory
29
Unlock relay2 time
(12-99 second). Default=
12 second
05
Enable/Disable Call
33
Temporary code
06
New access code
34
Special code
07
Delete access code
35
Temporary card
08
Clear all access code
36
Special card
09
Access code digit (4-8 digit).
Default is 4-digit
38
System acknowledge
(0-9). Default= 3
10
Add new card
39
Remote access
0= disable
1=enable (default)
11
Delete card
40
DTMF relay 1 (0-9).
Default=9
12
Clear all card
41
DTMF relay 2 (0-9).
Default=8
13
Set time
42
Relay 2 Mode
1= door control (default)
2= relay 2 trigger
simultaneously as relay 1
3= enable if function code
24 is enable
4= turn relay 2 on and off
On=7, Off=6
14
Set date
43
DND: do not disturb time
zone (0-9)
15
Initializing event recording
44
Disable Time zone relay
1, 2 or both
16
AUS= auto unlock schedule
(0-9 schedule)
45
Relay 1 and 2 unlock
timer
17
TMZ= time zone. 20 TMZ, 00-
20.
46
Firmware version
18
HLD= holiday zone. 20 HLD,
1-20
48 PBX enable. Default=
disable
19
Directory digit (2-4 digit).
Default is 2-digit
49 Edit Access code
20
AUXIN1
0= disable (default)
1= enable control by relay 1
open interval
2= relay 1 control by AUXIN1
50
Erase the memory to
factory default
21
AUXIN2
0= disable (default)
1= enable control by relay 2
open interval
2= relay 2 control by AUXIN2
51
Welcome screen
22
Do not disturb
0= disable (default), 1= enable
Log on to programming: Press
and
simultaneously then release,
the welcome message will stop
scrolling (repeat if screen still scrolls)
enter 4-digit “
MASTER CODE
” (0000
is default), the screen will show:
Select the “
Function Code
” from the
table
OPERATION
Opening the door remotely
press
(relay 1) or
(relay 2)
Opening the door with the access code
press
(display
screen will stop scrolling) then press a valid 4-digit access code.
Extending talk time
tenant must press
from the phone after
the time out warning beep.
Calling into the system
:
1. Enable function code 39 and function code 38 must be set 1-9
2. Call the system phone number, hear one beep if the system
answering the call.
3. Press
then 4-digit master code, hear one short beep
4. Press
to establish two way communication
5. Press
or to release the door.
OPERATION
Two ways call from the system
1. Press
to scroll name from A-Z or
to scroll name from Z-A
then press
to call name selected.
2. Press
wait for dial tone then press the directory number
QC1
IP
and QC2
IP
DEFAULT IP
IP: 192.168.1.230
SUBNET: 255.255.255.0
GATEWAY: 192.168.1.1
DNS: 192.168.1.1
USERNAME: Administrator
PASSWORD: 8888
WARNING:
DO NOT USE ON BOARD
12VDC and GND TO POWER A DOOR
STRIKE OR MAGNETIC LOCK
SEPARATE POWER MUST BE USED TO
POWER A DOOR STRIKE OR MAGNETIC
LOCK.