Nova-Tech CBK Series User Manual
Page 27
© Adam Equipment Company 2007
25
Parameter
Description
Options
Default
setting
F1 PCt
This parameter allows the user
to enter the Percent weighing
Function. See Section 10.7.
None
Enabled
always
F2 LLk
This parameter prevents the
normal user from changing the
limits with the help of a Limit
Lock.
With LLK set to Off (
oFF
),
the user is allowed to
change limits at any time.
With LLK set to Preset
(
PSt
), the user is allowed
to use one of the preset
limits only.
oFF
F3 LEd
This parameter sets the LED
indicator to off or on and the
LED type (whether LED’s are
on in the form of a continuous
bar or a spot LED).
bAr
- Bar type
Spot
- Spot type
oFF
- Off
bAr
F4 bEP
This
parameter
sets
the
Beeper to off or on. If set to
on, the beeper can further be
set
to
sound
when
the
weighing result is within or
outside the check-weighing
limits.
bP oFF
- Off
bP inL
- Within limits
bP otL
- Outside limits
(>20d)
bP inL
F5 CPS
This parameter allows setting
of a new Check weighing
password, must be entered
twice when asked. When
complete, it will display “
donE
”.
To be entered manually.
0000
F6 nCK
This
parameter
enables
negative
check
weighing
function with ability to do
negative tare.
on
oFF
on
NOTE:
1.
The Check weighing password is separate from the scale password,
see section 13.3.
2.
If the password is other than 0000, user must enter the password to
gain access to “F2 LLk”, “F3 LEd”, “F4 bEP”, “F5 CPS” and “F6 nCK
”.