beautypg.com

Nova-Tech CBK Series User Manual

Page 14

background image

© Adam Equipment Company 2007

12

• If a container is to be used, place this container on the platform

before entering parts counting and press

[Tare].

• Press [Count] to enter the Parts Counting mode. The display will

show the last sample size used. For example, “10 Pcs”.

• Either place 10 parts on the platform for determining the average

piece weight or use a different number of parts. For example, place
20 parts on the platform, press

[CE] to clear the last values and

then enter the value 20 using the numeric keypad.

• Press [Count] to weigh the samples and determine an average

piece weight.

• If the parts are too light to measure accurately, the count may

become faulty. It is suggested that the samples to be weighed
should each weigh more than the resolution of the scale.

• After the sample has been weighed the scale will count any other

parts added by applying the average piece weight to the weight of
the parts to be counted.

• The [Tare] key works normally during this time, so it is possible to

tare the display with a container on the platform or to enter a
preset tare value as described in section 10.2.2.

• During parts counting the display can be changed to show the net

weight, unit weight and number of parts by each time pressing the
[Func] key.