Dimension and capacity data – A.O. Smith VB/VW-500 User Manual

Page 4

background image

4

Minimum clearances to combustibles:
• 4” (102mm) rear
• 0” (0mm) top & sides
• 6” (152mm) vent

TABLE 1, GAS AND ELECTRICAL CHARACTERISTICS

Manifold Pressure

Maximum Supply Pressure

Minimum Supply Pressure

Model

Type of Gas

Inches W.C.

kPa

Inches W.C.

kPa

Inches W.C.

kPa

VB/VW-500, 750, 1000

NATURAL

-2 to 3.5

-.5 to .9

11.0

3.44

4.0

2.0

VB/VW-500, 750, 1000

PROPANE

-2 to -3.5

-.5 to .9

13.8

3.44

8.0

2.0

Minimum Pressures must be maintained during all operating conditions.
Electrical Power: 120v, 60hz, and 30 amps.

Models

VB/VW-500

VB/VW-750

VB/VW-1000

Dimensions

inches

mm

inches

mm

inches

mm

Flue Outlet Diameter

6

152

6

152

6

152

Air Intake Diameter

4

102

4

102

4

102

Water Inlet

2” NPT

Water Outlet

2” NPT

Gas Inlet

1” NPT

A

56

1422

62

1575

71

1803

B

30

762

30

762

30

762

C

30

762

30

762

30

762

D

45

1143

51

1295

59

1499

E

36

914

42

1067

48

1219

F

16.5

419

16.5

419

16.5

419

G

8

203

8

203

8

203

H

15

381

15

381

15

381

J

9

229

9

229

9

229

K

11.5

292

11.5

292

11.5

292

L

11

279

11

279

11

279

M

10.5

267

10.5

267

10.5

267

N

33

838

33

838

33

838

P

31

787

31

787

31

787

DIMENSION AND CAPACITY DATA

TABLE 2. ROUGH-IN DIMENSIONS

FIGURE 1.