Detroit Radiant Products Company MP Series User Manual
Page 5
When installing the tube heater system, clearances to combustibles for the model tube heater and
configuration must be maintained . Refer to Chart 1 .1 below to determine the required distances for your model .
5
MP
Series
Model Number
Mounting
Angle*
Sides
Front
Behind
Top
Below
MP-(25,30,40)-80[N,P]
0°
14
14
6
66
45°
39
8
10
66
with 1 side shield
0°
29
8
6
66
with 2 side shields
0°
16
16
6
66
20 ft . from burner
0°
7
7
6
30
MP-(30,40,50)-115[N,P]
0°
20
20
6
76
45°
58
8
10
76
with 1 side shield
0°
42
8
6
76
with 2 side shields
0°
20
20
6
76
20 ft . from burner
0°
7
7
6
30
MP-(40,50,60)-150[N,P]
0°
24
24
6
83
45°
58
8
10
83
with 1 side shield
0°
42
8
6
83
with 2 side shields
0°
23
23
6
83
20 ft . from burner
0°
11
11
6
46
MP-(50,60,70)-200[N,P]
0°
41
41
6
100
45°
63
8
10
100
with 1 side shield
0°
54
8
6
100
with 2 side shields
0°
30
30
6
100
20 ft . from burner
0°
11
11
6
50
1.0
Safety • Clearance to Combustibles
Chart 1.1 •
Clearance to Combustibles in Inches (See Figure 1 .1 for Mounting Angles)
Figure 1.1
•
Mounting Angles
0° Mounting Angle
45° Mounting Angle
0° Mounting Angle
with 1 Side Shield
(P/N: SSE)
0° Mounting Angle
with 2 Side Shields
(P/N: SSE)
Side
Side
Below
Top
Front
Behind
Below
Top
Front
Behind
Below
Top
Side
Side
Below
Top
The minimum end clearance for all models is 12 inches .
* Maximum mounting angle is 45° . Heaters mounted on an angle between 0° to 45° must maintain
clearances posted for 0° or 45°; whichever is greater .
The stated clearance to combustibles represents a surface temperature of 90°F (32°C) above room
temperature . Building materials with a low heat tolerance (such as plastics, vinyl siding, canvas, tri-ply,
etc .) may be subject to degradation at lower temperatures . It is the installer’s responsibility to assure that
adjacent materials are protected from degradation .