MaxPower Corp OceanAire Portable User Manual

Page 5

background image

3

Cooling Capacity is total BTU/HR at 80°DB/67°WB

high fan speed

Time delay fuses/circuit breakers are recommended.
EER determined with condenser discharge air

ducted
into another area on high fan speed.

CFM with free discharge.
Sound pressure, dB at 5 feet, commercial

configuration.

Amps & Watts at 208 Volts

Optional nozzles length
measured compressed.

MODEL

PAC1011
12

PAC1211
12

PAC1811
12

PAC2412 PAC3612 PAC3632 PAC6012 PAC6032 PAC6034 PAC6035

Cooling Capacity 1

10,100

12,700

18,010

24,020

36,050

36,050

60,050

60,050

60,050

60,050

Voltage

208/230/3 208/230/1 208/230/3

460/3

575/3

Cooling Amps6

9.0/4.5

12.0/7.0

15.5/7.8

12.3

22.5

14

34.0

25.0

12.4

11.4

Cooling Watts6

1030

1256

1590

2200

3360

3360

5900

5900

5900

5900

In Rush Current (Amps)

69.9

92.8

114.2

79

128.8

111.8

198.0

134.2

135.6

136.0

Fuse\Breaker (Amps)2

15

15

20

20

30

20

50

40

30

30

Plug Type

5-15P

5-15P

5-20P

6-20P

6-30P

L15-20P 6-50P L15-30P L16-30P L17-30P

EER 3

10.6

10.1

11.3

10.9

10.7

10.7

10.1

10.1

10.1

10.1

Compressor HP

3/4

1

1 1/2

2

3

3

5

5

5

5

Compressor RLA

7.4

9.3

11.4

8.3

17.9

11.4

28.0

20.0

8.2

6.4

Compressor LRA

42

58

65

49

88

77

169

123

59.6

40

Evap CFM 4

300

400

600

810

1310

1310

1950

1950

1950

1950

Evap Motor HP

1/15

1/15

1/5

1/3

1/2

1/2

1

1

1

1

Evap Motor Watts

200

200

210

350

375

375

550

550

550

550

Condenser CFM

580

580

930

1010

1390

1390

2200

2200

2200

2200

Condenser Motor HP

1/8

1/8

1/3

1/2

3/4

3/4

1

1

1

1

Condenser Motor Watts

280

280

450

330

460

460

750

750

750

750

Condensate Pump Head

(Pump Optional)

Sound Level 5

53

54

60

65

R-22 Charge Oz.

24

29

42

40

(A) Height with Casters

(B) Width

(C) Depth

(D) Height Without Casters

Net Weight

150

150

200

210

460

460

520

540

Shipping Weight

170

170

230

240

500

500

560

580

Shipping Volume

(E) Condenser Air Discharge

Optional Evap Nozzles

Optional Evap Duct Adapter

115/60/1 or 208/230/1

208/230/1

20 Feet

Pump Optional on these units

28 1/4

24 3/4

2 - 6 in. x 23 in. long

1 - 10 in. round

37 1/2

34 1/2

21

52 1/4

39

48 3/4

43

12 inch round

16 inch round

2 – 8 in. x 20 long

1 – 16 in. round

31 1/2

20 1/8

22 5/8

28 1/2

15

12 inch round

2-4 inch x15 inch long

1 –6 inch round

29

78

69

280

310

45

68

47

42 1/4

24 1/4

31

20 Feet

Pump Standard

airbossspecs1

Ambient Operating Range 65° to 105°

May operate to 55° if equipped with optional
factory installed hot gas bypass

Note: Condenser inlet air
plenum adds 13 inches
to dimension “C”.