beautypg.com

Property of magnum venus plastech – Magnum Venus Plastech CB-8000-xxx Resin Monitor User Manual

Page 38

background image

INSTALLATION AND OPERATIONS MANUAL

CB-8000-XXX

MAGNUM VENUS PLASTECH

REV 1.05

APRIL 2013

PAGE 7

975.1

980.1

985.1

990.1

995.1

PROPERTY OF MAGNUM VENUS PLASTECH

This print, or drawing is the property of MVP and is considered confidential or proprietary information. It is not to be copied, reproduced, used or disclosed in whole or in part, unless in reference to contracts or
proposals of this company. Nothing disclosed herein which is not publicy available may be used without prior written permission of MVP and all rights herein reserved.

--

--

--

--

--

--

--

945.1

--

--

940.1

--

--

935.1

--

--

--

--

--

930.1

--

--

--

--

925.1

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

ISSUED:

SHEET:

SCALE:

DATE:

APPROVED:

DATE:

DATE:

CHECKED:

FINAL ASSY

DRAWN:

TITLE:

SIZE:

SYSTEM:

DRAWING No:

REV:

NEXT ASSY

NO.

DASH

PART

PER ASSY

QTY REQD

FINAL

NEXT

APPLICATION

WIRING SCHEMATIC
ONBOARD INPUTS

CB-8000-XXX

4 OF 5

021113

BJS

1

B

950.1

955.1

960.1

965.1

970.1

--

--

920.1

--

--

--

915.1

--

--

--

--

910.1

--

--

--

--

--

905.1

--

--

--

900.1

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

1

2

3

4

5

6

7

8

LOGIC

SNK.

HI FREQ.

SNK.

RESET/USER INPUT SNK.

PWR UP RESET DISABLE

INPUT B DIRECTION CONTROL

HI FREQ.

MAG.

SRC.

LO FREQ.

SRC.

SRC.

ENABLE

INTENSITY ADJUST

LO FREQ.

1

2

3

4

5

6

7

8

LOGIC

SNK.

HI FREQ.

SNK.

RESET/USER INPUT SNK.

PWR UP RESET DISABLE

INPUT B DIRECTION CONTROL

HI FREQ.

MAG.

SRC.

LO FREQ.

SRC.

SRC.

ENABLE

INTENSITY ADJUST

LO FREQ.

1

ON

2

3

4

30

30

31 (BLK)

IN03

IN01

IN02

IN00

IN00

IN01

30

30

30

30

30

30

IN00 (BLK)

30 (BLU)

SHLD (WHT)

31 (BRN)

IN00 (BLK)

30 (BLU)

SHLD (WHT)

31 (BRN)

N.C.

N.C.

(GRY)

(GRY)

N.C.

(GRY)

IN03 (WHT)

REMOVE JUMPER
FROM TERMINAL
BLOCKS (IN00/IN01)

TO USE SECOND

DISPLAY AS GLASS
COUNTER

PLACE JUMPER ON

TERMINAL BLOCKS

(IN02/IN03) TO USE
REMOTE RESET ON
BOTH DISPLAYS

TBB3

TBB2

TBB1

TBB6

TBB5

TBB4

TBB2

TBB1

RED LION DISPLAY

LD2006P0 UPPER

TBB4

TBB6

TBB5

TBB3

INPUT COM

INPUT B

INP B

USR

INP COM

+EXC

RED LION DISPLAY

LD2006P0 LOWER

INP A

RED LION DISPLAY

CUB5

INPUT A

COM

INPUT COM

INPUT B

+EXC

INPUT A

COM

IN02 (BLU)

31 (BRN)

IN02

IN00

IN01

IN00

IN03

31

IN03

PB 02 RESET

LOWER DISPLAY

RESET/USER
(DIP SWITCH 5 ON)