CHAPTER 5-Calibration
Calibration
Navigate to the scale factor on all displays and set to 1.0000. Exit programming mode.
Reset all counters.
Using a container, dispense material. If volume is to be used the container must have volumetric
marks on it.
Once the container has been filled, record what the display reading is.
Using the net weight or volume from the container divide it by the monitor display.
This will be the adjusted scale factor that needs to be entered into all of the displays.
Example:
Dispensed material is 12.50 lbs. Monitor displayed weight is 8.56 lbs.
12.50/8.56= 1.46
1.460 should be entered into the scale factor for each monitor. Once this is done the display will
read the correct weight once you exit out of program mode.
Verify by resetting all counters and dispensing into bucket and checking vs. the displayed value.
If the reading has a large variance, repeat the above steps. If the variance is small, manipulate
the scale factor until the display is correct.