Magnum Venus Plastech CB-8000-xxx Resin Monitor User Manual
Page 16
INSTALLATION AND OPERATIONS MANUAL
CB-8000-XXX
MAGNUM VENUS PLASTECH
REV 1.05
APRIL 2013
PAGE 16
Press the PAR key.***
COUNTER A SCALE FACTOR
Display will read
A-ScF.
Scale Factor entry.
At this point you will have the option to set
the scale factor for calibration. Press the
SEL key if you wish to set the scale factor.
Press the SEL key to adjust the number and
use the RST key to move from number to
number. Please see Chapter 5-Calibration
section for setting this number.
Press the PAR key.
COUNTER A RESET ACTION
Display will read
A-rST.
Default setting
should be
ZEro
.
Press the PAR key.
COUNTER A COUNT DIRECTION
Display will read
A-dir.
Default setting
should be
NOr
.
Press the PAR key.
COUNTER A COUNT LOAD VALUE
Display will read
Cnt-Ld.
Default setting
should be
50.00
. This setting has no
bearing on this programming.
Press the PAR key.
COUNTER B BATCH COUNT ENABLE
Display will read
b-bAt.
Default setting
should be
NO
.
Press the PAR key.
COUNTER RESET AT POWER-UP
Display will read
r P-UP.
Default setting
should be
NO
.
Press the PAR key.
USER INPUT FUNCTION
Display will read
Usr-INP.
Default setting
should be
rESET
.
Press the PAR key.
Display will read
Pro or No
.
Press the PAR key.
This will exit programming mode.
*** Note: MVP recommends no more than 2 decimal points be used.