Magnum Venus Plastech CB-8000-xxx Resin Monitor User Manual
Page 15

INSTALLATION AND OPERATIONS MANUAL
CB-8000-XXX
MAGNUM VENUS PLASTECH
REV 1.05
APRIL 2013
PAGE 15
LD2006P0 display (large displays)
Using the PAR and SEL keys on the front of the display you will need to navigate to the correct module for
programming. Module 1-INP (inputs) is the only one that needs to be modified.
Once you have entered the module for programming use the following chart to navigate the module. The
greyed out parameters are not available.
The following is a step by step procedure on how to change the relevant settings. The only two settings that need
to be changed are the decimal point and the scale factor. All other settings are to remain at default.
Press the PAR key.
Display will read
Pro or No
.
Press the SEL key.
Display will read
1-INP
Press the PAR key.
COUNT MODE
Display will read
INP Ab
. Default setting
should be
Cnt ud.
Press the PAR key.
COUNTER A DECIMAL POINT***
Display will read
A-dPt
Decimal point setup.
At this point you will have the option to set
the decimal point. Press the SEL key if you
wish to set the decimal point and use the
RST key to set number of decimals.