Testing & Adjusting Manual

Rev. 01/2013

Page | 31

Pour Testing:


The same process and results that are used for testing the spray can be used for testing
a pour system. By pouring a bead of material in an up and down” zig zag” pattern then
observing the results.





























Result 8:
Material delivered on the catalyst pump down-stroke (from the top of the stroke to the
bottom) is not curing or slow cure (see figure above).

Indicates: No catalyst is being delivered on the down-stroke.


Probable Cause: Worn or damaged inlet body.

Worn or damaged inlet body ball.
Worn or damaged inlet body O-ring.

Solution: Replace worn and damaged parts, see Service and Repair Manual.

Start Pour Test

Direction of gun travel

End Pour Test

B

B

B

T

T

Start Pour Test

Direction of gun travel

End Pour Test

B

B

B

B

T

T

T

Start Pour Test

Direction of gun travel

End Pour Test

B

B

B

B

T

T

T