Magnum Venus Plastech CHOP CHECK FLUID CCPLS-1000 User Manual
Page 27

CCPLS-1000 Fluid Section Manual
Rev. 08/2012
Page | 27
Final Assembly
–
1.
Apply a light film of the proper lubrication to the inside of both ends of Foot Valve
Housing.
2.
Slide the correct end of Foot Valve Housing over the Priming Rod and Intake
Valve and onto the Cylinder.
3.
Apply a light film of the proper lubrication to O-Ring and install onto Lower Valve
Seat.
4.
Install Lower Valve Seat over the Priming Rod and into the Foot Valve Housing.
5.
Install the four Tie Rods (CCPLS-1020) into the Outlet Body and tighten.
6.
Apply the proper lubrication to O-Ring and install onto Priming Valve Housing.
7.
Install the Priming Valve Housing and O-Ring over the Priming Rod and into the
Foot Valve Housing and onto the Tie Rods (CCPLS-1020). Align the notch in the
Priming Valve Housing opposite the outlet hole in the Outlet Body.
8.
Thread the four Hex Nuts (7201-12-8) onto the Tie Rods (CCPLS-1020) and
tighten them firmly against the Priming Valve Housing.
9.
Apply a thin film of the proper lubrication to Piston Seal (CCPLS-1024) and install
onto Priming Piston.
10. Adjust the Displacement Rod in the pump so just the wrench flats are exposed
out of the Packing Nut (CCPLS-1006).
11. Place the Priming Piston onto the Priming Rod.
12. Place onto Hex Cap Screw (F-HB-06F-12) one Backup Washer (CCPLS-1028)
the Relief Washer (CCPLS-1025) and the last Backup Washer (CCPLS-1028).
13. Apply a drop of Loctite to the threads of Hex Cap Screw (F-HB-06F-12) and
thread it into the end of the Priming Rod. Tighten only till the Priming Rod starts to
spin. Use caution not to over tighten, the Relief Washer may become damaged.