Magnum Venus Plastech CHOP CHECK FLUID CCPLS-1000 User Manual
Page 19

CCPLS-1000 Fluid Section Manual
Rev. 08/2012
Page | 19
Fluid Section Removal:
WARNING: When removing Pump Fluid Section, Hoses and Resin Surge
Chamber, be sure to bleed off fluid pressure from the system before
disconnecting. Release Surge Chamber charge before removing Surge Chamber.
System may be under pressure and cause injury.
Note: The Fluid Section can be rebuilt in place or easily removed and taken to
a workbench. Flushing the fluid section with suitable cleaning agent can
make the rebuild process much easier.
TO REMOVE THE FLUID SECTION FROM THE PUMP ASSEMBLY:
1. Put the pump into the lowest position of the down stroke.
2. Disconnect the resin hose from the side of the Pump fluid section.
Warning: Be sure to remove fluid pressure from the system before
disconnecting resin hose, tie rods or surge chamber. System may be under
pressure and can cause injury.
3. Remove the Sleeve Clip, lift up the Shell Retainer and remove the two Half
Shells from the Rod ends.
4. Remove the four Hex Head Bolts holding the fluid section to the Pump Mount
Plate (CCP-1008).
5. Remove the four Hex Head Bolts (F-HB-06C-16) holding the fluid section to the
Support Plate (CCP-1009).
6. Remove the two Hex Nuts from the Support Rod.
7. Shift the Ram Control valve into the Ram up position, move the ram up until the
pump mount plate will allow the pump fluid section to be removed.
Note: As you disassemble, lay the parts out on a towel or rag in the order you
take them apart. This will help you remember how they go back together.
Inspect each part for wear or damage and note parts that require replacement.