DAILY SHUT-DOWN for INFUSION UNIT


ACTIVITIES MUST BE DONE IN THE SEQUENCE SHOWN, AND MUST BE
CHECKED OFF AS COMPLETED.

ACTIVITY NO.

ACTIVITY

CHECK AS
COMPLETED

Priority

Put on Respirator as specified for spray painting,
Protective Clothing, Eye Protection, and PVC Gloves

1

Properly Flush the gun and Mixer assembly with solvent.

2

Turn off the main air ball valve at the air manifold.

3

Release the Flush Tank pressure by lifting the relief ring.

4

Remove the Mixer assembly – inspect and clean it with
solvent replace as needed.

5

Remove the Mix Housing and clean as needed. Check the
Catalyst Injector and Seals for proper operation.

6

Wipe the gun block face with a clean rag.

7

Check the weep holes on the top of the gun block for leaking
material – tighten the packing nuts as needed.

8

If the gun is not mounted - hang the gun with the gun block
exit holes facing downwards.



ABNORMAL CONDITIONS OBSERVED AND CORRECTED

Abnormal Condition

a

a

a

a when
corrected



OPERATORS NAME _________________________________ DATE: ____________


SIGN OFF WHEN SHUT DOWN CHECKS ARE COMPLETED: __________________