Start-up instructions – Magnum Venus Plastech System One FRP 1100-1-1 User Manual
Page 8

FRP SystemOne
Start-Up Instructions
1. Removing Unit From Crate.
With the crate laying flat. Open the top panel and remove the
components as needed.
a. Cart
b. Pump and Column Assembly.
c. Boom, Hose, and Gun Assembly.
d. Resin Filter/Surge Chamber Assembly.
e. Suction Wand Assembly.
f.
Component Box.
g. Catalyst Jug.
h. Solvent Tank.
Charging the Resin Surge Chamber:
1.
Open ball valve below inline resin filter.
2.
To charge the resin surge chamber, use the air hose with the
female quick disconnect (charging hose) and insert over the male
quick disconnect at the top of the resin surge chamber. Push down
on female quick disconnect for 5 to 10 seconds and disengage.
3.
Close ball valve below in-line resin filter.
Pressurizing Fluids:
1.
Slowly increase resin pump regulator, 50 psi would be a good
starting point.
2.
Pull the pivot pin using the slide arm. Use slow up and down
motion to pressurize the catalyst pump for several strokes or until
firm.
3.
Pin the pivot pin into the slide arm.
Gun Set-Up:
1.
Install turbulent mixer into mix chamber and install tip. For
longer turbulent mixer life, do not over tighten the nozzle cap.
2.
Test the spray pattern, make pump pressure adjustment for
required resin outputs.
3.
Thread either one or two strands of glass into chopper motor. Use
chopper motor pivot to adjust glass entry into resin fan. Center the
glass into the resin fan using the eccentric stud.
5