10. Attach Suction Wand to Resin Pump.
a. Check all fittings on the wand assembly to make sure they are
airtight.
b. Attach the wand assembly to the foot valve port of the resin pump.
11. Hose connections.
a. Connect the black resin hose from the gun to the outlet fitting on
the resin filter
b. Connect the catalyst hose from the gun to the outlet of the catalyst
pump assembly.
c. Attach the red air hose from the gun to the fitting on the regulator
labeled gun.
d. Attach the yellow poly flush hose from the gun to the outlet fitting of
the solvent tank.
e. Attach the small red air supply hose from the flush regulator to the
input fitting on the solvent tank.
f.
Attach the large red air hose from the pump regulator to the power
cylinder of the resin pump.
g. Attach the ground wire from the gun to the electrical grounding lug
on the pump power head.
h. Remove the catalyst poly tubes from the component box.
i.
Cut the ½ inch dia. poly line, with the clamps, to 26 inches long.
Clamp one end to the outlet of the catalyst jug and the other end to
the inlet of the catalyst pump. Make sure clamps are airtight.
j.
Connect the 3/8-inch poly line to the relief valve on the catalyst
pump assembly and insert the other end into the hole in the top of
the catalyst jug.
12. Mount Exhaust Silencer to power head of resin pump.
a. Remove the exhaust deflector from the power head of the resin
pump, (4 screws). Screw silencer into the pipe threads of the
exhaust port.
NOTE
If icing of silencer becomes a problem. Remove the silencer
and replace the exhaust deflector. Noise level will be higher
with silencer removed.