beautypg.com

Wetting out unit – Magnum Venus Plastech System One FRP 1100-1-1 User Manual

Page 7

background image

FRP SystemOne

Wetting Out Unit

Air Supply:

1.

Use minimum ½” air hose supply to the system. Air requirements,
18 CFM

2.

Open incoming air supply ball valve.

3.

Set regulator labeled gun at 90 to 100 psi. Tighten packing nuts on
the gun and trigger the gun 15 to 20 times. Tighten packing nuts

again and repeat gun triggering.

Priming Solvent:

1.

Open solvent tank lid and fill tank ¾ full. Install lid on tank and
close the relief valve located on the top of the lid. Set flush tank
pressure at 50 to 60 psi.

2.

Push the flush valve on the side of the gun block to test solvent
flush.

Priming Catalyst to Gun:

1.

Tighten the catalyst packing nut ¼ turn.

2.

Fill the two gallon catalyst jug ¾ full, purge the air out of the
catalyst feed line by slightly tilting the catalyst jug.

3.

Lock the gun in the open position. Remove the pivot pin from
the catalyst slide arm linkage. Use the slide arm to hand prime
catalyst out to the gun until a steady stream is achieved. Do not
reinstall pivot pin at this time.

Priming Resin to Gun:

1.

Insert the resin suction wand into a 55-gallon drum or resin.

2.

Tighten the resin pump packing nut until tight. Fill packing nut
cavity ¾ full with suitable oil.

3.

With gun locked in the open position, slowly increase resin pump

regulator pressure until pump is running at a slow but steady rate.
Allow pump to run until a fairly steady stream of resin is being
dispensed. Close the gun and flush the gun head.
4.

Increase resin pump pressure to 100 psi. Allow the unit to set
under static load for 15 to 30 minutes to seat the resin packing set.

5.

Clamp or tape the resin return hose coming from the bottom of the
in-line resin filter to the resin pickup wand, into the resin drum. Turn
the resin pump regulator to zero. Slowly open the ball valve at the

bottom of the resin filter to drain the fluid pressure.

4