1. Tighten all hose fittings and fluid connections to make sure they are

tight.

2. Check electrical grounds, gun to pump and pump to earth ground.

3. Check all clamp brackets, pump column, slave arm bracket, manifold

clamp, etc. To make sure they will not move when unit is in operation.

4. Check the mounting of catalyst pump to make sure clevis pins are

secure.

5. Make sure exhaust silencer is secured to the power cylinder of the

resin pump.

6. IMPORTANT: Snug up the packing nut at the top of the catalyst

pump Approximately ¼ turn.

7. Snug up, tighten, the resin pump packing be inserting two rods into

the holes in the oil cup at the top of the resin pump fluid section. Turn
clockwise until packing is snug.

8. Tighten the gun valve rod packing nut until it is very snug.

IMPORTANT: Activate the gun trigger 10 - 15 times then tighten
the packing nut.
Repeat this tightening procedure 3 times to make
sure the gun valve rod packing is tight.

FRP SystemOne
Installation & Set-Up

Checklist