beautypg.com

Frp system one maintenance schedule – Magnum Venus Plastech System One FRP 1100-1-1 User Manual

Page 12

background image

FRP SystemOne

4-Hour Oil Chopper Air Motor
For every four hours of operation, the chopper air motor should be oiled.
Push down on the quick disconnect, pull back on the clip, pull it off the bar
fitting and add one or two drops of oil for every four hours of operation.

Daily Relief Valve Check
We start to get accumulating a lot of catalyst in the hose. We want to
drain that off and see how much catalyst that we accumulate in the relief
valve hose, daily. If it’s excessive, we want to replace the ball in the relief
valve.

Daily Water Trap Check
Water traps should be drained daily. Just push the bottom button and
drain any water that may have collected in line.

Weekly Power Head Lubrication
Turn the pump regulator down to zero. Loosen the air hose fitting and add
10 to 15 drops of 90-weight non-detergent gear oil.

Weekly Fluid Section Packing Nut Check
Check the fluid section for any resin coming up through the packings into
the cavity. If you see any resin, tighten the packing nut. Add oil if needed.

Weekly Catalyst Packing Nut Check
Look for any catalyst bleeding up through the packings. If you see any
leakage, tighten the packing nut an eighth of a turn.

9

Chapter

3

FRP SystemOne
Maintenance Schedule