Assembly Procedures:

1.

Install 7301-9-013 (O-Ring), and 4101-8-1 (Inlet Tube Fitting) onto
4101-7-1 (Inlet Body).

2.

Insert the 9201-1-14 (7/16” SS Ball) into the 4101-7-1 (Inlet Body).

3.

Position a 7301-9-014 (O-Ring) onto the notched end of the
4102-6-1 (Cylinder).

4.

Screw the notched end of the 4102-6-1 (Cylinder) into the 4101-7-1
(Inlet Body). Turn by hand until it bottoms on the Inlet Body, “snug
tight”.

5

NOTE

T

T

T

T

Tak

ak

ak

ak

ake car

e car

e car

e car

e care not to dama

e not to dama

e not to dama

e not to dama

e not to damag

gg

gge the O-ring on the thr

e the O-ring on the thr

e the O-ring on the thr

e the O-ring on the thr

e the O-ring on the threads

eads

eads

eads

eads.....

NOTE

Care must be taken to not scratch or dent SS Ball.

Care must be taken to not scratch or dent SS Ball.

Care must be taken to not scratch or dent SS Ball.

Care must be taken to not scratch or dent SS Ball.

Care must be taken to not scratch or dent SS Ball.