FRP SystemOne

FRP SystemOne
Catalyst Surge Chamber Reassembly

Chapter

5

1.

Install a 7301-9-013 (O-Ring) over the threaded end of the 4104-6-1
(Return Tube Fitting).

2.

Insert the 9201-1-4 (1/8” SS Ball) into the 4104-4-1 (Surge Relief
Valve Body).

3.

Insert the 4104-5-1 (Relief Valve Spring) into the 4104-6-1 (Return
Tube Fitting) over the SS Ball.

4.

Thread the 4104-6-1 (Return Tube Fitting) into the 4104-4-1 (Surge
Relief Valve Body) compressing the Spring between the Tube Fitting
and the Ball.

5.

Fasten the Catalyst Surge Chamber Assembly to the Metering
Pump Assembly.

The Surge Chamber Assembly is complete