Magnum Venus Plastech PATRIOT PAT-CCP-LS-0590-SS User Manual
Page 17

PAT-CCP-LS-0590 Chop Check Fluid Section Manual
Rev. 02/2012
Page | 17
Fluid Section Removal:
1.
Remove the Ram and Pump from the material.
2.
Place a piece of plastic or paper under the Ram and Pump to catch any dripping
material.
3.
Put the pump into the lowest position of the down stroke.
4.
Shift the Ram Control valve into the down position; allow pump and Ram to travel
to the lowest position.
5.
Disconnect the resin hose from the side of the Pump fluid section.
Warning: Be sure to remove fluid pressure from the system before disconnecting
resin hose, tie rods or surge chamber. System may be under pressure and can
cause injury.
6.
Remove the E-Ring (F-ER-1.00-HD), lift up the Sleeve (PAT-PA-9109) and remove
the two Connectors (APP-9096).
7.
Remove the four Hex Nuts (F-HN-06C) and Lock Washers (F-SW-06) holding the
fluid section to the Adapter Tie Rods (PAT-CCP-0522).
8.
Shift the Ram Control valve into the Ram up position, move the ram up until the
Adapter Shaft (PAT-CCP-0521) clears the Transition Plate (PAT-CCP-0503) this
will allow the pump fluid section to be removed.