Liquid Controls SP1200 User Manual

Page 5

background image

“SET-UP” menu will
be displayed:



“2-RTD” should not be selected. This is a factory calibration function.

Select “3-Factor” by pressing “3” key.
***NOTE: To exit the “SET-UP” menu press “RESET” key.






Select desired product and press corresponding key.







To retain displayed Rfactor: Press “RESET” key, display will advance.
To change displayed Rfactor: Press “CLEAR/FEED” key. Enter new Rfactor,
Press “ENTER” key, display will advance.







To retain displayed Tfactor: Press “RESET” key, display will advance.
To change displayed Tfactor: Press “CLEAR/FEED” key, Enter new Tfactor,
Press “ENTER” key, display will advance.







To continue “FACTOR”: Select desired product, press corresponding key.

Repeat.

To exit the “FACTOR” menu: Press “RESET” key, “SET-UP” menu will be displayed:

1 = Clock
2 = RTD

3 = Factor
4 = More

Product Number?

Product Number?

0 = LOX
.30456

Rfactor?

0 = LOX
.005076

Tfactor

PRODUCT SELECTOR

0 = LOX

1 = LIN

2 = LAR

3 = LCO2

4 = N20

5 = CCO2

6 = MAPP

7 = LPG