Following is a list of commands available and their corresponding functions:
(C) Whenever a CHR$(67) is received, the 350S enters the set clock mode. This mode
operates exactly the same as the setting messages via the keypad, except commands
are received from the serial port.
The following commands are used when setting both the clock and messages.
(sp) CHR$(32) move cursor 1 location to the right.
( H) CHR$(8) move cursor 1 location to the left.
( ) CHR$(62) increment data at cursor location.
( ) CHR$(60) decrement data at cursor location.
(C)CHR$(67) set data to space at cursor location (message only)
(R)CHR$(82) reset clock/message to default setting
(N)CHR$(78) toggle introductory message. *
( Z)CHR$(26) store clock/message as it appears and return to setup menu
*The introductory message is printed when power is first turned on.
The following commands are available only on the 350S with ticket storage function.
These commands will only function when the unit is in the setup mode.
(T) Whenever a CHR$(84) is received, the 350S will begin a stored ticket dump in
exactly the same format as printed on the built-in printer. The operator is still promoted
on the LCD if it is desirable to erase stored tickets.
(D) Whenever a CHR$(68) is received, the 350S begins a HEX dump of all data stored
in the 2048 byte ticket memory. If it is desirable to erase stored tickets after the
memory dump, the letter (e) CHR$(101) should be transmitted while the memory dump
is taking place. If (e) is received by the 350S, all stored tickets will be erased. NOTE:
The operator is not prompted to erase tickets when using this function.