InstallatIon overvIeW

Installation Overview

In order to maintain IECEx compliance, the SP714-S2i is shipped as part of an assembly with a Sponsler turbine

flowmeter. A complete installation of the flowmeter and pulse amplifier assembly includes the physical installation of

the flowmeter and the electrical installation of the SP714-S2i. Guidelines for the physical installation of the flowmeter

can be found in the Sponsler turbine flowmeter manual. Instructions for the electronic installation of the SP714-S2i are

included in this manual.

Installation overview for the SP714-S2i:

1. Install Sponsler turbine flowmeter (with SP714-S2i) into system piping. Sponsler Turbine Flowmeter Installation Manual
2. Wire the SP714-S2i to a pulse acquisition device and set the S1 switches to the preferred output signal characteristics. Page 7
3. Perform field test and adjust the input signal sensitivity (if necessary). Page 11

Use the proper cable glands, conduit connectors, cables,

conduit, and installation procedures when wiring the SP714-S2i.

Installations must be in full accordance with national and local

codes to maintain the hazardous location ratings on the product.

Observe National and Local Codes

WIrInG the outPut sIGnal confIGuratIons

The SP714-S2i can be set to one of three configurations: 2-wire Standard, 3-wire TTL Sourcing, and 3-wire Open

Collector. The 2-wire Standard configuration translates the output signal from the turbine flowmeter’s pickup coil into

a current value. 2-wire connections are effective transmitting the signal over long distances. The 3-wire TTL Sourcing

configuration translates the output signal from the turbine flowmeter’s pickup coil into a voltage value. The output

of the 3-wire TTL Sourcing configuration is driven either positive or negative internally. The 3-wire Open Collector

configuration translates the output signal from the turbine flowmeter’s pickup coil into a voltage value. The output is

driven by an “Open Collector” transistor.
Each configuration requires a specific positioning of the two S1 switches, specific

wiring connections (to the power supply and the pulse acquistition device), and a

resistor(s) spliced into the +V leg from the power supply (optional for the 3-wire TTL

Sourcing configuration).
The best configuration for your application is determined by the specifications of the

pulse acquistion device (typically a flow computer or electronic register) receiving

the SP714-S2i signal and the electrical characteristics of the application.

SW1

S1

J U 4

D1

D2

GND

TB2

S2

R1

TB1

ON

ON

1 2

GND

1

S1 Switches

Materials required: not supplied with SP714-S2i

• 18 AWG stranded wire in shielded cable, UL Listed For

ambient temperatures above 70°C, use field wiring suitable for 20°C

above maximum ambient temperature.

• ½-14 NPT cable glands Use Ex d certified cable glands only.

• Connectors for pulse acquisition device or DC power supply

See “Observe National and Local Codes” on this page.

• PTFE tape or pipe sealant