background image

dImensIons and sPecIfIcatIons

Weight

• 1.2 lbs (0.54 kg)

Materials of Construction

Housing

• Aluminum Alloy ADC12

• Powder Coat: Corro-Coat PE 74-141 Polyester

Adapter (to turbine meter boss)

• Stainless Steel

Cable Entry

• ½"-14 NPT

Temperature Range

Operating

• -40 to 176 °F (-40 to 80 °C)

Storage

• -76 to 257 °F (-60 to 125 °C)

Specifications

Input Voltage

• 6-28 VDC; 83 mA maximum @ 24 VDC

• Protected against polarity reversal

Signal Input

Frequency

• 2 kHz maximum over operating temperature in all modes

Amplitude

• 10 mV p-p minimum sine or square wave

Impedance

• 50 KΩ

Sensitivity Field

• Adjustable by potentiometer (R1)

Output Signal Characteristics

See following page.

front

sIde

sP714-s2i

and turbIne

floWmeter

dimensions

4