beautypg.com

Laurel Electronics LAUREATE SERIES SCALE-WEIGHT METER User Manual

Page 19

background image

19

FiLtr

Filtering
(continued)

00000

Input signal filtering.
Can be applied to dis-
play, setpoint, analog
output, data output.

0

Autofilter Readings

1

Batch avg

16

60 Hz 50 Hz

2

Moving avg

. 07 s .08 s

3

Moving avg

.14

.16

4

Moving avg

.28

.34

5

Moving avg

.57

.68

6

Moving avg

1.13

1.36

7

Moving avg 2.27

2.72

8

Moving avg 4.53

5.44

9

Moving avg 9.06

10.88

A

Moving avg

18.1

21.7

B

Moving avg

36.2

43.4

C

Moving avg

72.5

85

D

Moving avg

145

174

E

Moving avg

290

348

F

No filter

d

.

dddd

Decimal point flashes.

d

.

dddd dd

.

ddd ddd

.

dd dddd

.

d ddddd

.

.

ddddd

Press to shift the decimal point.

Scaling method “Scale and Offset” if selected under

SEtuP

SCALE

Scale factor

0.0000 0.0000 0.0000

0.0000 0.0000

0.0000

Select digit to flash.

Select

-9

thru

9

for flashing first digit,

0

thru

9

for other flashing digits. Select decimal point
location when decimal point is flashing.

OFFst

Offset value

0.0000 0.0000 0.0000
0.0000 0.0000

Select digit to flash.

Select

-9

thru

9

for flashing first digit,

0

thru

9

for other flashing digits. Decimal point
location is selected by

dEC.Pt

.

Scaling method “Coordinates of 2 points” if selected under

SEtuP

. Appears before _

InPut

.

Lo In

.

Low signal input.

0.0000 0.0000 0.0000
0.0000 0.0000

Select digit to flash.

Select

-9

thru

9

for flashing first digit,

0

thru

9

for other flashing digits. Decimal point is set
by input range chosen.

Lo rd

Desired reading at
Lo In.

0.0000 0.0000 0.0000
0.0000 0.0000

Select digit to flash.

Select

-9

thru

9

for flashing first digit,

0

thru

9

for other flashing digits. Decimal point is set
by

dEC.Pt

.

Hi In

.

High signal input.

0.0000 0.0000 0.0000
0.0000 0.0000

Select digit to flash.

Select

-9

thru

9

for flashing first digit,

0

thru

9

for other flashing digits. Decimal point is set
by input range chosen.

Hi rd

.

Desired reading at
Hi In.

0.0000 0.0000 0.0000
0.0000 0.0000

Select digit to flash.

Select

-9

thru

9

for flashing first digit,

0

thru

9

for other flashing digits. Decimal point is set
by

dEC.Pt

.

_

tArE

Tare value

0.0000 0.0000 0.0000
0.0000 0.0000

Select digit to flash.

Select

-9

thru

9

for flashing first digit,

0

thru

9

for other flashing digits. Decimal point
location is selected by

dEC.Pt

.