Controlled Products Systems Group DTEK110VAC User Manual
Page 5

Technical Specifications
Power: the detector is available in the following voltages, 12V AC/DC, 24V AC, 24V DC, 110V
AC, 220V AC. maximum current draw 100mA.
Low power detector is available with maximum current draw of 60mA
Temperature:
-40F to + 180F
Environmental Protection: Circuit board is conformally coated
Enclosure:
Extruded anodized aluminum,
Height = 3.25 inches 83 mm
Width = 2.56 inches 40 mm
Depth = 3.65 inches 90 mm
Output Relays:
5A/125 V AC standard version, 1A/125 V AC low current version
Connector:
86CP11 compatible with 11pin Octal DIN rail mountable socket or
wire harness
Surge Protection:
The detector is protected with neon discharge lamps, Zener diodes
and surge arrestors.
Loop Input:
Transformer isolated
Grounded Loop:
The loop isolation transformer allows operation with poor quality
loops.
Loop Inductance Range:
20 to 2000 micro henries with Q factor of 5 or higher.
Tuning:
Detector automatically tunes to the loop after power application or
reset.
Tracking:
Detector automatically tracks and compensates for environmental
changes
Power Indicator:
Green LED solid light indicates power
Loop Failure Indicator:
Green LED blinks indicates loop problem
Loop Failure Memory:
Green LED blinks with fast consecutive blinks indicates past loop
problem that healed.
Detect Indicator:
Red LED solid light indicates detection
Extend Indicator:
Red LED blinks after a car left the loop indicates time extend
feature
Sensitivity:
is set by 10 position rotary switch
Frequency:
is set three position toggle switch
Infinite Presence Mode:
DIP switch selectable presence
Limited 4 Minutes
Presence Time:
DIP switch selectable
Second Presence Relay:
DIP switch selectable
Pulse On Exit / Entry:
DIP switch selectable
Fail Safe / Secure :
DIP switch selectable
Filter:
DIP switch selectable 2 seconds
Extended Detection:
DIP switch selectable 3, 6 and 9 seconds
DTEK.lwp Created: March 23, 1998 Revised: January 16, 2003 10:44AM Pages:5