Maintenance and adjustments, Speed level, Adjustment guides – Controlled Products Systems Group 4024 User Manual
Page 19: Locating safe-t-beam pairs
Maintenance and Adjustments
6
ADjUSTMENT GUIDES
(continued)
Speed Settings (DC motors only)
Speed settings are pre-programmed at the factory for the maximum
speed. Speed settings should not need adjustment with this unit.
However, travel speed for the opener can be adjusted to a slower
speed in both the Open and Close directions, to minimize wear on
heavier sectional doors.
NOTE: One-piece doors are automatically set to the slowest speed
during Limits programming and cannot be adjusted.
There are 3-speed settings available for sectional doors. Please note
that speed may be affected by door weight and balance, along with
condition of door components and tracks.
Speed Adjustment
OFF
Flashes BLUE 3 Times
PROGRAM
SET
PROGRAM
SET
PROGRAM
SET
1
2
3
4
5
PROGRAM
SET
LOCKS IN OPENING SETTING.
Then the Current Speed setting
for
CLOSING travel will display.
SEE CHART IN NEXT COLUMN.
7
6
Press and hold for
about 10 seconds
or until both LEDs
turn BLUE.
Then release.
BLUE
BLUE
BLUE
BLUE
Action
LED Indication/Result
Press twice.
Press and
release.
Press either until
you reach the
desired setting.
Press and
release.
Press either until
you reach the
desired setting.
Press and
release.
OFF
Flashes BLUE 3 Times
NOTE: Depending on the criteria
mentioned above, you may not
have the option to increase speed.
OFF
Flashes BLUE
3 Times
NOTE: Depending on the criteria
mentioned above, you may not
have the option to increase speed.
LOCKS IN CLOSING SETTING.
FLASH BLUE
FLASH BLUE
SPEED SETTINGS DONE
Then the Current Speed setting
for
OPENING travel will display.
SEE CHART IN NEXT COLUMN.
Both LEDs FLASH
BLUE to confirm setting.
Speed Level
Powerhead LEDs
ROUND LED
LONG LED
High
Medium
Low
RED
RED
PURPLE
PURPLE
BLUE
BLUE
LED indicator colors:
OFF
Blue
Purple
Red
NOTE: PowerLift
®
900, GPower
™
900 openers DO NOT have speed
adjustments.
LOCATING SAFE-T-BEAM PAIRS:
Source (Red LED) and Sensor (Green LED)
Single Garage Door
• Determine which side of the garage receives direct sunlight.
• Position the Source (Red LED) on the direct sunlight side
Multiple Garage Doors
• NEVER position Safe-T-Beam modules where signals will cross.
• Place the Source (Red LED) Safe-T-Beams on adjacent doors facing
in opposite directions.
NOTE: Direct sunlight creates interference with Safe-T-Beam Sensor
(Green LED). Sensor modules CAN be positioned further away from
door opening if necessary to avoid sunlight but no further off the wall to
maintain alignment with paired Source module.
Red
LED
Red
LED
Sun
Sun
Green
LED
Green
LED
One Door
Garage
One Door
Garage
Two Door
Garage
Two Door
Garage
Three Door
Garage
Three Door
Garage
Red
LED
Red
LED
Green
LED
Green
LED
Red
LED
Red
LED
Red
LED
Red
LED
Green
LED
Green
LED
Red
LED
Red
LED
Red
LED
Red
LED
Green
LED
Green
LED
Green
LED
Green
LED
Green
LED
Green
LED
Red
LED
Red
LED
Sun
Sun
Green
LED
Green
LED
One Door
Garage
One Door
Garage