Maintenance and Adjustments
6
CAUTION
Door closing force is FACTORY set and requires no adjustment
for normal operation.
•
NEVER adjust the force settings to compensate for damage,
including an unbalanced door, binding door track, or broken
spring.
• Perform monthly a CONTACT REVERSE TEST. See page 8.
ADjUSTMENT GUIDES
Force Settings
Force settings are pre programmed at the factory and “learned”
during the Open/Close Limit settings steps (see pages 6-7). For normal
use, these settings should not need adjustment with this unit.
However, conditions possibly requiring adjustment are:
1. Doors with very stiff weather seals.
2. Doors that start down, STOP, and reverse before closing.
3. Doors that start up, but STOP before they completely open.
Force Adjustment
(continued next page)
Force Level
Powerhead LEDs
ROUND LED
LONG LED
LED indicator colors:
OFF
Blue
Purple
Red
Force Level 1
BLUE
BLUE
BLUE
BLUE
Off
Off
Off
Off
Force Level 3
Force Level 4
PURPLE
PURPLE
PURPLE
PURPLE
Off
Force Level 6
Force Level 7
RED
RED
RED
RED
Off
Force Level 9
Force Level 2
Force Level 5
Force Level 7
PROGRAM
SET
PROGRAM
SET
The Current
UP FORCE SETTING
will display. SEE CHART IN NEXT
COLUMN.
Action
LED Indication/Result
Press and hold
both up and
down buttons
2 seconds or until round
LED turns RED.
Press either
until you reach
desired setting.
Press and
release.
Press either
until you
reach the
desired setting.
Press and
release.
USE CHART IN NEXT COLUMN
USE CHART IN
NEXT COLUMN
LOCKS IN SETTING.
Then the New
DOWN FORCE
SETTING will display.
OFF
RED
OFF
BLUE
Flashes 3 Times
BLUE
Flashing
OFF
BLUE
BLUE
LOCKS IN SETTING.
Both LEDs turn
BLUE then OFF
confirms both
FORCE Settings are reset.
BLUE
BLUE
OFF
OFF
FORCE SETTINGS DONE