beautypg.com

Contact reverse test, Up/down force erase - open/close travel limit – Controlled Products Systems Group 1024 User Manual

Page 22

background image

PN# 3642036534, 02/26/2010 REV. 1

22

FIG. 6-6

2 x 4 under center of door opening.

CONTACT REVERSE TEST

The force adjustments and limit switch settings
MUST BE COMPLETED before testing.

1. Testing.

‡ Open garage door using wall button.

– Place a 2" x 4" board (laid flat) under center

of garage door opening (Fig. 6-6).

‡ Close door using wall button.

‡ When door contacts board, the door must stop

(within 2 seconds) and reverse direction
returning to open position.

2. Adjustment.

‡ If the door does not properly reverse.

– Check to see if door has "close" limit

programmed. It should not have reached its
"close" limit before hitting board.

– If the door STOPS but does not reverse,

decrease "CLOSE FORCE" control
setting slightly (turn it counter-clockwise).

‡ Test again. Repeat as necessary until door

reverses upon contacting board.

CLOSE

1. Press and hold both of the "SET" buttons

( & ) together until the green indicator
light blinks (about 5 seconds).

2. All close and open travel limit settings are

erased. Then follow the steps on page 20 to
reprogram close and open travel limits.

NOTE: The opener will not close the door
automatically unless the Safe-T-Beam

®

System is

installed.

SET

SET

1. By turning the Close Force Control

clockwise,

the CLOSE force can be increased. By turning
the Close Force Control

counter-clockwise,

the CLOSE force can be decreased. Set the
CLOSE force level at the minimum force required
to close door without reversing.

2. Once the desired level is selected, this stores the

maximum force level for the CLOSE direction in memory.

3. By turning the Open Force Control

clockwise, the

OPEN force can be increased. By turning the Open
Force Control

counter-clockwise, the OPEN

force

can be decreased. Set the OPEN force level at the
minimum force required to open door without stopping.

4. Once the desired level is selected, this stores

the maximum force level for the OPEN direction
in memory.

OPEN

CLOSE

OPEN

CLOSE

UP/DOWN FORCE

ERASE - OPEN/CLOSE TRAVEL LIMIT

OPEN

FORCE

CLOSE

Down Force

Control

Adjustment

Up Force

Control

Adjustment

ROTATE

CLOCKWISE

ROTATE

COUNTER-CLOCKWISE

(Increasing Force

(Decreasing Force

FIG. 6-5

Force Control Adjustment.

This manual is related to the following products: